BQVYC - QUICK DRY ENAMEL UNDERCOAT, 6-6

  • MSDS: BQVYC
  • Manufacturer: PPG INDUSTRIES INC
  • Product Name: QUICK DRY ENAMEL UNDERCOAT, 6-6
  • National Stock Number: 8010-00N037698
Product Identification

Product ID:QUICK DRY ENAMEL UNDERCOAT, 6-6
MSDS Date:06/05/1990
FSC:8010
NIIN:00N037698
MSDS Number: BQVYC

Responsible Party
PPG INDUSTRIES INC
260 KAPPA DR
PITTSBURGH, PA 15238
US

Emergency Phone: 304-843-1300

Info Phone: 412-492-5555;800-245-2590

Cage: 47695

Contractor
PPG INDUSTRIES INC
PITTSBURGH, PA 15272 US

Telephone: 1-800-245-2974 (CAL HYPO)

Cage: 47695

Ingredients

1); (CALCIUM CARBONATE)

CAS: 471-34-1

RTECS: FF9335000

Fraction By Weight: 50-55%

OSHA PEL N/K

ACGIH TLV: N/K


TITANIUM OXIDE; (TITANIUM DIOXIDE)

CAS: 13463-67-7

RTECS: XR2275000

Fraction By Weight: 10-15%

OSHA PEL 15 MG/M3 TDUST

ACGIH TLV: 10 MG/M3 TDUST; 9293


SOLVENT NAPHTHA (PETROLEUM) MEDIUM ALIPHATIC; (MEDIUM

CAS: 64742-88-7

Fraction By Weight: 20-25%


FILM FORMERS, RESINS, AND ADDITIVES

Fraction By Weight: 10-15%


USED, FOG NOZZLES ARE PREFERABLE.

RTECS: 9999999ZZ


AVOID LONG TERM &

RTECS: 9999999ZZ


INHALING MASS QTYS OF TITANIUM DIOXIDE DUST IN

RTECS: 9999999ZZ


INVOLVED IN MFR OF PIGMENT INDICATE NO INCR RISK OF

RTECS: 9999999ZZ


DUSTS FROM COATINGS IS VERY LIMITED. SINCE

RTECS: 9999999ZZ


OF AIRBORNE CONTAMINANTS AGAINST WHICH

RTECS: 9999999ZZ


LEL IN FIRE AND EXPLO HAZARD DATA BELOW STATED LIMIT,&

RTECS: 9999999ZZ


ON SURFACES COATED WITH THIS PRODUCT.

RTECS: 9999999ZZ

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE: INGEST: HARMFUL/FATAL IF
SWALLOWED. EYE: CAUSES IRRIT. SKIN: MAY CAUSE MOD SKIN IRRIT.
INHAL: VAP & SPRAY MIST MAY BE HARMFUL IF INHALED. VAP IRRIT EYES,
NOSE,& THROAT. RPTD EXPOS TO HIGH VAP C ONC MAY CAUSE IRRIT OF RESP
SYS & PERM BRAIN & NERV SYS DMG. INTENTIONAL MISUSE BY DELIB CONC &
INHAL CONTENTS (ING 6)
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:EYE WATERING, HEADACHES, NAUSEA, DIZZINESS, AND
LOSS OF COORDINATION ARE INDICATIONS THAT SOLVENT LEVELS ARE TOO
HIGH. REDNESS, ITCHING, BURNING SENSATION AND VISUAL DISTURB MAY
INDICATE EXCESSIVE EYE CONT. DRYNESS, ITCHING, CRACKING, BURNING,
REDNESS, & SWELLING ARE CONDITIONS ASSOCIATED WITH EXCESSIVE SKIN
CONTACT.
Medical Cond Aggravated by Exposure:NOT APPLICABLE.

First Aid

First Aid:INGEST:DO NOT INDUCE VOMIT. EYE:FLUSH IMMED W/PLENTY OF WATER
FOR AT LST 15 MINS. SKIN:REMOVE PROMPTLY BY WIPING, FOLLOWED BY
WATERLESS HAND CLEANER & SOAP & WATER. INHAL: REMOVE TO FRESH AIR.
APPLY A RTF RESP & OTHER SUPPORTIVE MEASURES ASREQD. OTHER: IF ANY
OF FOLLOWING OCCUR DURING/FOLLOWING USE OF PROD, CONT POIS CNTRL
CNTR, EMER ROOM/PHYS IMMED. HAVE MSDS INFO AVAIL:INGEST, EXCESSIVE
(SUPDAT)

Fire Fighting

Flash Point Method:PMCC
Flash Point:107F,42C
Lower Limits:1%
Extinguishing Media:USE NFPA CLASS B EXTING (CARBON DIOXIDE, DRY
CHEM/UNIVERSAL AQUEOUS FILM FORMING FOAM) DESIGNED TO EXTING NFPA
(SUPDAT)
Fire Fighting Procedures:WEAR NIOSH/MSHA APPRVD SCBA & FULL PROT
EQUIP.WATER SPRAY MAY BE INEFT.WATER SPRAY MAY BE USED TO COOL CLSD
CNTNRS TO PVNT PRESS BUILDUP & POSS (SUPDAT)
Unusual Fire/Explosion Hazard:KEEP CNTNRS TIGHTLY CLSD.ISOLATE FROM
HEAT, ELEC EQUIP,SPARKS,& OPEN FLAMES. CLSD CNTNRS MAY EXPLO WHEN
EXPOS TO EXTREME HEAT.DO NOT APPLY ON HOT SURFS.(SUPDAT)

Accidental Release

Spill Release Procedures:PROVIDE MAX VENTILATION. ONLY PERSONNEL
EQUIPPED WITH PROPER NIOSH/MSHA APPRVD RESP & SKIN & EYE PROT
SHOULD BE PERMITTED IN AREA. REMOVE ALL SOURCES OF IGNIT. TAKE UP
SPILLED MATL W/SAWDUST, VERMICUL ITE/OTHER ABSORB MATL & PLACE INTO
CNTNR FOR DISP.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:DO NOT STORE ABOVE 120F. STORE LARGE
QUANTITIES IN BUILDINGS DESIGNED AND PROTECTED FOR STORAGE OF NFPA
CLASS II COMBUSTIBLE LIQUIDS.
Other Precautions:IF MATL IS PART OF MULTIPLE COMPONENT COATING SYS,
READ MSDS(S) FOR OTHER COMPONENT/COMPONENTS BEFORE BLENDING AS
RSLTG MIX MAY HAVE HAZ OF ALL PARTS. CNTNRS SHOULD BE GROUNDED WHEN
POURING. AVOID FRE E FALL OF LIQ IN EXCESS OF FEW INCHES.

Exposure Controls

Respiratory Protection:OVEREXP TO VAPS MAY BE PVNTD BY ENSURING VENT
CNTRLS. VAP EXHST/FRESH AIR ENTRY. NIOSH/MSHA APPRVD (TC-23C) PAINT
SPRAY/AIR SUPP (TC-10C) RESP MAY ALSO REDUCE EXPOS. READ RESP MFR'S
INSTRUCTIONS & LIT ERATURE CAREFULLY TO DETERM TYPE(ING 10)
Ventilation:PROVIDE GEN DILUTION/LOC EXHST VENT IN VOL & PATTERN TO
KEEP CONC OF INGS BELOW LOWEST SUGGESTED EXPOS LIMITS, (ING 11)
Protective Gloves:IMPERMEABLE GLOVES.
Eye Protection:CHEM WORK GOG W/FULL LGTH FCSHLD .
Other Protective Equipment:WEAR PROT CLTHG, INCL IMPERMEABLE APRON
CONSTRUCTED OF PVA, NEOPRENE RUBB, NITRILE RUBBER, BUTYL RUBBER OR
LATEX RUBBER.
Work Hygienic Practices:CLEAN OR DISCARD CONTAMINATED CLOTHING AND
SHOES.
Supplemental Safety and Health
EXTING MEDIA:CLASS II COMBUST LIQ FIRES.EXPLO HAZ:TOX GASES MAY FORM
WHEN PROD IS CONTACTED BY FLAME/HOT SURFS.HAZ DECOMP PRODS:
INCL:CARBON MONOXIDE, OXIDES OF NITROGEN.FIRST AID PROC:EXPOS TO
CORR M ATL, PERSISTENT SKIN/EYE IRRIT/BRTHG DFCLTYS.FIRE FIGHT
PROC: AUTOIGNIT/EXPLO WHEN EXPOS TO EXTREME HEAT.IF WATER(ING 5)

Chemical Properties

Boiling Pt:B.P. Text:>212F,>100C
Vapor Pres:2.1
Vapor Density:HVR/AIR
Spec Gravity:1.57
Evaporation Rate & Reference:17 (BUOAC=100)
Solubility in Water:0.2%
Appearance and Odor:VISCOUS LIQUID WITH AN ODOR CHARACTERISTIC OF
SOLVENTS LISTED.
Percent Volatiles by Volume:43.80

Stability

Stability Indicator/Materials to Avoid:YES
STRONG ALKALIES, STRONG MINERAL ACIDS, OR STRONG OXIDIZING AGENTS.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:MAY PRDCE HAZ DECOMP PRODS WHEN
HEATED; WELDING, BRAZING/FLAME-CUTTING ON SURFS COATED W/PROD MAY
PRDCE FUMES (SUPDAT)

Disposal

Waste Disposal Methods:WASTE MATERIAL MUST BE DISPOSED OF IN ACCORDANCE
WITH FEDERAL, STATE, PROVINCIAL, AND LOCAL ENVIRONMENTAL CONTROL
REGULATIONS. EMPTY CONTAINERS SHOULD BE RECYCLED OR DISPOSED OF
THROUGH AN APPROVED WA STE MANAGEMENT FACILITY.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.